Information:
Severn Glocon butterfly valve, 36 inches
Condition:
Due to backflow of gases in the furnace, the temperature surged above 400°C causing the Soft Seat (PTFE) to melt and the valve body to rust.
MOG’s Solutions:
-
Disassembled the valve components;
-
Machined and replaced the Soft Seat (PTFE) with a new one;
-
Reassembled and tested the valve according to API 598.