Information:
Choke valve.
Condition:
The valve body is leaking due to damaged Soft Seat and O-Ring.
MOG’s Solutions:
-
Shut off the pipelines and valves related to the choke valve and ensured safety for personnel;
-
Disassembled the choke valve components to access the damaged valve body;
-
Machined the Soft Seat (PTFE);
-
Replaced the entire Soft Seat and O-Rings with new ones;
-
Conducted testing after the repair.